Filter Results By:

Products

Applications

Manufacturers

Low Frequency

Low Frequency 30 to 300 kHz.

See Also: VLF, ELF


Showing results: 586 - 600 of 728 items found.

  • Passive Probe, 500 MHz, 10:1, 1 MOhm/10 MOhm

    PP020-1 - Teledyne LeCroy

    Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.

  • 500 MHz Passive Probe, 2.5mm, 10:1, 10 MOhm

    PP023-1 - Teledyne LeCroy

    Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.

  • 500 MHz Passive Probe, 5mm, 10:1, 10 MOhm

    PP024-1 - Teledyne LeCroy

    Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.

  • 500 MHz Passive Probe, 5mm, 10:1, 10 MOhm

    PP025-1 - Teledyne LeCroy

    Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.

  • 500 MHz Passive Probe, 5mm, 10:1, 10 MOhm

    PP026-1 - Teledyne LeCroy

    Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.

  • Frequency Conversion Rotating Magnetic Fla

    MT-2XCF - Mitech Co., LTD.

    MITECH MT-2XCF rechargeable frequency conversion rotating magnetic flaw detector is based on principle that the leakage magnetic field can absorb the magnetic powder. Make use of magnetic yoke magnetized the workpiece of ferromagnetic material. If there has defects it will produce leakage magnetic field that will adsorb magnetic powder. We could detect the flaw by observing the density of adsorption magnetic powder. It adopts large capacity lithium battery. By the inverter and the phase shifted signal processor to provide power for the detector, it solves the shortcomings of traditional magnetic particle detector relying on the 220V power supply. It has low power consumption and can continuous work for more than 6 hours. And the battery can be charged when the detector is on and off. Especially suitable for the field testing. It can choose the current frequency according to the flaw depth with unique frequency conversion communication design, that improve the detection sensitivity. It’s widely used in aircraft manufacturing, boiler and pressure vessels and other fields. It is a necessary professional precision instrument of quality control, in-service safety monitoring and life assessment.

  • Diversity Receiver

    R400a - Lectrosonics, Inc.

    The R400a is a high performance, triple-conversion, frequency synthesized, UHF receiver fully compatible with all Lectrosonics 400 series transmitters, and a number of analog models. The proprietary audio processing includes a DSP (digital signal processor) for very low distortion and a superior signal to noise ratio. The DSP eliminates a compandor and its artifacts to provide exceptional audio quality when operating in its native hybrid mode. Special DSP algorithms also provide compatibility modes for use with Lectrosonics 100 and 200 Series analog transmitters.

  • High-Performance USB-Controlled PLL Synthesizers

    Fairview Microwave Inc.

    Rugged, SMA-connectorized designs that support a USB 2.0 interface with a PC supplying DC power and GUI command control. They cover a broad range of frequency bands from 25 MHz to 27 GHz. These USB-Controlled PLL Synthesizers deliver output attenuation that is adjustable up to 50 dB in 1 dB steps and high output power levels ranging from +10 dBm to +19 dBm typical. Phase noise is as low as -108 dBc/Hz at 100 MHz offset and phase locked speed is 1 msec typical.

  • Power Amplifiers

    Analog Devices Inc.

    Analog Devices MMIC-based GaN and GaAs power amplifiers cover the low hundred MHz frequency range up through and including components in the W band (75 GHz to 110 GHz). In addition to components, our portfolio also includes GaN-based power amplifier modules with output power exceeding 8 kW. Designed for excellent linearity at high output power, our power amplifiers maintain good heat dissipation and high reliability at elevated temperatures for the wide variety of wired and wireless applications that they are used in.

  • RF High Power Amplifier Modules

    Analog Devices Inc.

    Analog Devices MMIC-based GaN and GaAs power amplifiers cover the low hundred MHz frequency range up through and including components in the Ka-band (29 GHz to 31 GHz). Our portfolio also includes GaN-based power amplifier modules with output power exceeding 8 kW. Designed for excellent linearity at high output power, our power amplifiers maintain good heat dissipation and high reliability at elevated temperatures for the wide variety of test, radar, and aerospace and defense applications that they are used in.

  • Rugged Portable Phase Stable RF Analyzer Cables

    Fairview Microwave Inc.

    Fairview Microwave’s line of phase stable RF analyzer cables consists of 19 models designed to deliver optimal amplitude and phase stability with flexure. These portable test cables feature VSWR as low as 1.2:1 and a maximum operating frequency of 27 GHz, depending on the model. These rugged RF test cables feature crush resistance of 1,200 psi and an operating temperature range of -55°C to +105°C. These test cables for handheld RF analyzers are offered with 7/16, N, SMA, TNC or 3.5mm connector options.

  • Bump Tester

    KD-163 - King Design Industrial Co., Ltd.

    *Comply with IEC-68-2-29 testing specification(10g/ 16ms、15g/6ms、 40g/6ms、100g/2ms).*Easy installation and simple operation; Low noise; no maintenance required; function holds long.*Well-designed and no resonant-structure, air anti- vibration pad can effectively isolate floor vibration.*Accelerometer adopts repeated measurement and adjustable half-sine wave generator; to control the data is precise.*Magnesium alloy platform is anodized, Servo motor cam to drive, and can adjust the frequency automatically.*The adjustable acceleration value and shock domain is patent design (1ms-13ms).

  • 2-18GHz Digitising Receiver

    DR068-M1 - Teledyne Defence & Space

    Teledyne Defence & Space (TDS) DR068-M1 Digitising Receiver combines a state of the art broadband frequency measurement receiver with a high dynamic range successive detection log video amplifier to realise a high probability of intercept receiver. Digital signal processing techniques are utitlised to derive pulse parameters which are packaged into a PDW and transferred via a low latency Gigabit Ethernet interface. The DR068-M1 enables new and existing systems to incorporate a wideband high POI pulse detection capability with minimal integrating effort.

  • TINYig Oscillators

    Teledyne RF & Microwave

    The smallest available oscillator in the industry, Teledyne Microwave's TINYIG is an ultra-low phase noise YIG-tuned oscillator (YTO) that provides superior phase noise frequency up to 20 GHz. Uniquely designed to be RoHS compliant, these YIG TO-8 oscillators exploit the principle of magnetic resonance to generate a clean, low phase noise microwave signal over broad tuning ranges. It can greatly simplify system designs, thus reducing costs, eliminating the need for extra components, and reducing the risk of malfunctions of complicated electronic connections and operations.

  • Up Converters

    Macom Technology Solutions Holdings Inc.

    MACOM's upconverters are widely used in point-to-point radio, broadband communications, and RADAR applications. Operating up to a frequency of 86 GHz, our upconverters feature an integrated image reject (balanced) mixer, LO buffer, and RF buffer. Some products also include LO multiplication and variable gain, all within a single chip. Available in die, or SMT lead-free QFN and LGA packages, our upconverters boast excellent performance with adjustable bias, high linearity and image rejection with low LO leakage

Get Help